Industrial & networks
Cable, 4–20 mA, Modbus, network and OEE sums for the people who build and run plants.
11 tools · free · no upload

- How much traffic will it make?OPC UA subscription calculator
- Will my Modbus line keep upModbus polling calculator
- How far does my Wi-Fi reach?Wi-Fi range estimator
- Is this cable too thin?Voltage drop calculator
- Where does this subnet start and end?Subnet calculator
- How many amps is this load?Three-phase power calculator
- What does 12 mA mean?Analog signal scaling
- What temperature is this resistance?Pt100 calculator
- What is the line really achieving?OEE calculator
- Can the line meet demand?Takt time calculator
- What do these registers mean?Modbus register decoder
How the industrial and network calculators work
Each tool takes your own settings and shows the load or the range that follows from them, with the formula and the assumptions beside the result. They are estimates from the numbers you enter. Nothing connects to a server, a device or a network, and nothing leaves your browser.
Which tool for which problem
- A client subscribes to many OPC UA items: estimate the traffic per second and per hour.
- A Modbus line is slow or overloaded: the Modbus polling calculator gives the requests, frame bytes, bus load and the shortest interval.
- Wi-Fi does not reach the far room: the Wi-Fi range estimator works from transmit power, antenna gains, frequency and walls.
- A long cable run: the voltage drop calculator gives the drop, the voltage at the load and the smallest cable size within your limit.
- A transmitter reads 12.4 mA: the 4–20 mA calculator turns current, voltage, percent, raw PLC counts and engineering units into each other.
- Two registers from a Modbus device make no sense: the Modbus register decoder shows them as integers, floats and text in all four byte orders.
- An IP plan for a plant network: the subnet calculator gives the range, broadcast and host count, and splits a network into subnets.
- How well a machine or line runs: the OEE calculator gives availability, performance, quality and where the time went.
Questions
Do these tools talk to my equipment?
No. They compute estimates from the settings you type. No port is opened, no bus is scanned and no server or device is contacted.
Why do real figures differ from the result?
OPC UA servers differ in chunk sizes, batching, padding and keep-alive timing, and bursts or retransmissions add traffic. The Wi-Fi estimate is free-space path loss with a path-loss exponent and wall losses, not a site survey.
Why is the Modbus load over 100%?
The rows ask for more traffic than one poll interval allows. Raise an interval, lower a count, or raise the baud rate or link speed. The result also shows the shortest interval a full pass needs.
Why does 5 GHz reach less than 2.4 GHz at the same power?
Path loss grows with frequency, so the same link budget runs out sooner at 5 or 6 GHz. Real walls also absorb more at higher frequencies than the simple model assumes.
Books for this kind of work
All books
Agentic AI in the BrowserUse cases for privacy-first, browser-native AI workflows: the same do-it-on-your-device idea fixmint is built on.
$4.99Get it on Gumroad
HARDWARE THEORYTwenty years of computing hardware explained: cores, clocks, memory and storage, and why your devices behave the way they do.
$4.99Get it on Gumroad

